1.
Chinese Medical Equipment Journal ; (6): 25-27, 2017.
Article in Chinese | WPRIM | ID: wpr-511349

ABSTRACT

Objective To explore the formation process of vacuum pressure differential of micro power negative pressure technology to facilitate its clinical application.MethodsThe formation of negative pressure differential and changes of negative pressure values in enclosure space were studied which was formed by liquid aspiration after the compressive polyvinyl alcohol foam material was enclosed.Micro power negative pressure technology was applied to the treatment of the right ear necrosis patient after focal cleaning,and the efficacy was observed.Results Medical adhesive film was raised gradually during the expansion of polyvinyl alcohol foam due to liquid aspiration,and then the enclosure space extended increasingly to form local vacuum negative pressure.The range of maximal negative pressure was between-110 and-200 Pa,and the mean maximal negative pressure value was-132.7 Pa.Micro power negative pressure technology behaved well in healing the wound.Conclusion Micro power negative pressure technology gains advantages in reliability and easy operation over other technologies and products,and may be a new choice for healing of refractory wounds.

2.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-585034

ABSTRACT

The remote monitoring and alarming system of the level & pressure of the liquid-oxygen tank employes two microprocessors and remote control technique to fulfill its functions.With a cable and a video connection wire involved,the system is simple,safe,reliable and lightingproof.

3.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-590899

ABSTRACT

Objective To propose an improved C-means segment method based on Gibbs random field accelerated by GPU.Methods The parallel computation of pixel shades was used to take the place of the classical point-by-point method of CPU.By this way,the efficiency was higher than merely using the CPU computation.Results The efficiency of computation was improved over 400%.The load of CPU was reduced and the effect of accelerator was obvious.Conclusion The improved C-means segment method based on Gibbs random field accelerated by GPU enhances the clinical application of image segmentation,the computer rate of which is improved distinctly and closely to real time.[Chinese Medical Equipment Journal,2008,29(2):6-9]